23 pages were found matching tag octavius lll.
- FREE ACCESS VMAT monthly QA using two techniques: 2D ion chamber array with an isocentric gantry mount and an in vivo dosimetric device attached to gantry (P. Myers et al), Journal of Radiotherapy in Practice (2013)
- Establishing an optimized patient-specific verification program for volumetric modulated arc therapy (Alfredo Serna,Fernando Mata, Vicente Puchades) Medical Dosimetry 38 (2013), Issue 3 , 274-279
- FREE ACCESSQuantifying Alterations in Flattened and FFF Beam Characteristics from a Gantry Mounted, in Vivo Beam Delivery Verification System on a TrueBeam Linac (AC Riegel et al) Med. Phys. 38, 3587 (2011)
- FREE ACCESS IMRT Pre-Treatment Plan and In-Vivo Verification with 2D-ARRAYs and Multi-Wire Ionisation Chambers (B Poppe, H Looe, A Ruehmann, D Harder, and K Willborn) Med. Phys. 35, 2759 (2008)
- FREE ACCESS Modelling the response of a LINAC-headmounted multi-wire transmission detector for prediction of signals for IMRT plan verification (D. Johnson et al) Poster Presentation at ESTRO 2012, Barcelona, Spain
- FREE ACCESS Enhanced accuracy of IMRT photon fluence profile surveillance: iterative resolution correction of the DAVID chamber (H K Looe et al) 2010, Phys. Med. Biol. 55, 3981
- FREE ACCESS Implementing RapidArc into clinical routine: A comprehensive program from machine QA to TPS validation and patient QA (Ann Van Esch et al) Med. Phys. 38, 5146 (2011)
- FREE ACCESS Comparison of four commercial devices for RapidArc and sliding window IMRT QA (V. Chandraraj et al) JACMP 12 (2011), 338
- FREE ACCESS Characterization of responses of 2D ARRAY seven29 detector and its combined use with octavius phantom for the patient-specific quality assurance in rapidarc treatment delivery (S. A. Syamkumar et al))
- FREE ACCESS IMRT DOSIMETRIC VERIFICATION PROCEDURE (S. Pellejero, S. Lozares, A. Forner, U. Iriondo, A. Otal , Pedro Mari Soto, F. Mañeru, M. Martín, S. Miquelez, A. Rubio) Poster published on ESTRO 2011
- FREE ACCESS Considerations of Reference Level Definition for IMRT Plan Verification and Application of a Three Dimensional Gamma Index Analysis (B. Poppe et al) Medical Physics, Vol. 36, Issue 6
- FREE ACCESS DOSIMETRIC CONSIDERATIONS FOR SPINAL SINGLE FRACTION INTENSITY MODULATED STEREOTACTIC RADIOSURGERY WITH BRAINLAB NOVALIS (D. Zucca Aparicio et al) Poster published on ESTRO 2011
- FREE ACCESS Evaluation of PTW Seven29 for tomotherapy patient specific quality assurance and comparison with ScandiDos Delta4 (P. Myers et al) Journal of Medical Physics, April 2012; 37(2): 72-80
- FREE ACCESS Effects of dose scaling on delivery quality assurance in tomotherapy (Nathan Whitmore et. al.) Journal of Applied Clinical Medical Physics, Vol. 13, No. 1 (2012)
- FREE ACCESS Volumetric Modulated Arc Therapy with Simultaneous Integrated Boost for Locally Advanced Rectal Cancer (S. Cilla et al) Clinical Oncology Volume 24, Issue 4, May 2012, 261-268
- FREE ACCESS COMPARISON OF THREE COMMERCIAL PHANTOMS FOR QUALITY ASSURANCE (QA) OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) (E. Pignoli, T. Giandini, C. Stucchi, V. Mongioj and G. Zonca) Poster published on ESTRO 2011
- FREE ACCESS COMMISSIONING OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) WITH PTW OCTAVIUS PHANTOM ACCORDING TO THE AAPM TG119 (T. Giandini, E. Pignoli, C. Stucchi, V. Mongioj and G. Zonca) Poster published on ESTRO 2011
- On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom, Ann Van Esch et al., Med. Phys. 34 (10), October 2007, 3825 - 3837
- DAVID - a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques (B Poppe et al) 2006, Phys. Med. Biol. 51 1237-1248
- Clinical performance of a transmission detector array for the permanent supervision of IMRT deliveries (B Poppe et al) 2010 Radiotherapy & Oncology Volume 95, Issue 2, Pages 158-165
- Dose verification for respiratory-gated volumetric modulated arc therapy (J. Qian et al.) Phys. Med. Biol. 56 (2011) 4827-4838
- Three Dimensional Gamma-Index Analysis and Considerations of the Reference Level Definition for Dosimetric IMRT Plan Verification with 2D Ionisation Chamber Arrays (B. Poppe et al) 2009, IFMEB Proceedings, Vol. 25/1, pp. 248 - 249
- Pre-clinical evaluation of respiratory-gated delivery of volumetric modulated arc therapy with RapidArc (Giorgia Nicolini et al) 2010 Phys. Med. Biol. 55 N347